UCP
Primers
Universal Clear Primer for Wood

    PRODUCT DESCRIPTION
    UCP is the ideal bare wood primer for use before painting or varnishing. It can be used above and below water.
    * Suited to both High Performance and Conventional varnishes.
    * Bonds to the wood for excellent adhesion
    The fast drying formulation is tougher and more durable than conventional primers.

    PRODUCT INFORMATION
    Colour YPA600-Clear
    Finish Gloss
    Specific Gravity 1.1
    Volume Solids 50% 
    Typical Shelf Life 2 yrs
    VOC (As Supplied) 467 g/lt
    Unit Size 375 ml

    DRYING/OVERCOATING INFORMATION

    Drying

    5ºC 15ºC 23ºC 35ºC


    Touch Dry [ISO] 5hrs 4hrs 3hrs 2hrs


    Overcoating
    Substrate Temperature
    5ºC 15ºC 23ºC 35ºC
    Overcoated By Min Max Min Max Min Max Min Max


    Perfection Undercoat &nbsp24hrs &nbsp36hrs &nbsp12hrs &nbsp28hrs &nbsp6hrs &nbsp24hrs &nbsp4hrs &nbsp16hrs
    Perfection Varnish &nbsp24hrs &nbsp36hrs &nbsp12hrs &nbsp28hrs &nbsp6hrs &nbsp24hrs &nbsp4hrs &nbsp16hrs
    Primocon &nbsp24hrs &nbsp36hrs &nbsp12hrs &nbsp28hrs &nbsp6hrs &nbsp24hrs &nbsp4hrs &nbsp16hrs
    UCP &nbsp24hrs &nbsp36hrs &nbsp12hrs &nbsp28hrs &nbsp6hrs &nbsp24hrs &nbsp4hrs &nbsp16hrs
    Yacht Primer &nbsp24hrs &nbsp36hrs &nbsp12hrs &nbsp28hrs &nbsp6hrs &nbsp24hrs &nbsp4hrs &nbsp16hrs


    Note:If maximum overcoating time has been exceeded, sand using 80-180 grade (grit) paper. All international varnishes are compatible with UCP and can be applied using the overcoating time observed for Perfection varnish.

    APPLICATION AND USE
    Preparation BARE WOOD: Sand smooth with 80-180 and then 280 grade paper. Clean surface by brushing, dusting or wiping. If wiping with solvent allow to dry completely before applying first coat.


    Method Contains Isocyanates which may be harmful to lungs, read the health and safety data section before use. Avoid a 'bitty' finish by applying only on clean dry timber. Do not exceed recommended film thickness or bubbling may occur.


    Hints Thinner YTA006 Thinners No.9
    Cleaner YTA006 Thinners No.9
    Ventilation and Humidity Control The minimum humidity is 35%, drier conditions than this will retard curing.


    Some Important Points DO NOT SPRAY. Do not use in conjunction with Intertox. Do not use below 5°C. Ambient temperature should be minimum 5°C/40°F and maximum 35°C/95°F. Substrate temperature should be minimum 5°C/40°F and maximum 35°C/95°F. Product temperature should be minimum 5°C/40°F and maximum 35°C/95°F.


    Compatibility/Substrates Can be overcoated with all varnishes in International range. Not suited to oily timbers such as Teak and Iroko. On oily timbers such as Teak use Perfection for Teak or thinned varnish instead of UCP.


    Number of Coats 1-4 as per specification


    Coverage (Theoretical) - 20.00 (m²/lt)

    (Practical) - 17.50 (m²/lt)


    Recommended DFT 25 microns dry
    Recommended WFT 50 microns wet


    Application Methods Brush, Roller

    TRANSPORTATION,STORAGE AND SAFETY INFORMATION
    Storage GENERAL INFORMATION:
    Exposure to air and extremes of temperature should be avoided. For the full shelf life of UCP to be realised ensure that between use the container is firmly closed and the temperature is between 5°C/40°F and 35°C/95°F. Keep out of direct sunlight.
    TRANSPORTATION:
    UCP should be kept in securely closed containers during transport and storage.

    Safety GENERAL: Contains isocyanates which may be harmful to the respiratory tract. Read the label safety section for Health and Safety Information, also available from our Technical Help Line.
    DISPOSAL: Do not discard tins or pour paint into water courses, use the facilities provided. It is best to allow paints to harden before disposal.
    Remainders of UCP cannot be disposed of through the municipal waste route or dumped without permit. Disposal of remainders must be arranged for in consultation with the authorities.

    IMPORTANT NOTES The information given in this sheet is not intended to be exhaustive. Any person using the product without first making further written enquiries as to the suitability of the product for the intended purpose does so at their own risk and we can accept no responsibility for the performance of the product or for any loss or damage (other than death or personal or injury resulting from negligence) arising out of such use. The information contained in this sheet is liable to modification from time to time in the light of experience and our policy of continuous product development.

    and International are registered trademarks of Akzo Nobel.

    Regional Addresses
    Head Office
    International Paint Ltd
    P O Box 20980
    Oriel House
    16 Connaught Place
    London W2 2ZB
    United Kingdom
    tel: +44 (0) 171 479 6000
    fax: +44 (0) 171 479 6500
    European Region
    International Paint Ltd
    Stoneygate Lane
    Felling, Gateshead
    Tyne & Wear NE10 0JY
    United Kingdom

    tel: +44 (0) 191 469 6111
    fax: +44 (0) 191 438 3977
    Asia Region
    International Paint Singapore (Pte) Ltd
    449 Tagore Industrial Avenue
    01-03 Hong Joo Industrial
    Building
    Singapore 787820

    tel: +65 6453 1981
    fax: +65 6453 1778
    Australasia Region
    International Paint
    115 Hyde Road
    Yeronga, Brisbane
    Queensland 4104
    Australia

    tel: +61 (0) 7 3892 8866
    fax: +61 (0) 7 3892 4287
    North America Region
    International Paint Inc
    2270 Morris Avenue
    Union
    New Jersey 07083
    USA
    tel: +1 (0) 908 686 1300
    fax: +1 (0) 908 686 8545
    South America Region
    International Paint
    Rod Rap tavares, KM 18.5
    Predio Administrativo 11
    Butanta CEP 05577-300
    Sao Paulo, Brazil

    tel: +55 (0) 11 3789 2000
    fax: +55 (0) 11 3789 2200


    Ref:
    Issue Date:
    Supersedes:
    05000027
    1-Mar-2003
    14-Feb-2003