    PRODUCT DESCRIPTION
    VC Tar2 is a 2-component epoxy primer providing osmosis protection to GRP boats and anticorrosive protection to steel and alloy surfaces. For use below water only.
    * Self-levelling to give an excellent finish
    * Easy to apply - overcoatable within hours
    * No sanding required between coats
    * Offers excellent barrier to water for osmosis protection and treatment
    * Ideal primer base for all VC antifoulings

    PRODUCT INFORMATION
    Colour YEA728-Off White, YEA729-Black Please check availability of full colour range. Not all colours are available in every country.
    Finish Semi-gloss
    Specific Gravity 1.18
    Volume Solids 60.5% 
    Mix Ratio 7:1 by volume (as supplied) , Converter/Curing Agent - YEA730
    Typical Shelf Life 2 yrs
    VOC (As Supplied) 339 g/lt
    Unit Size 1 Lt 2.5 Lt

    DRYING/OVERCOATING INFORMATION

    Drying

    5°C 15°C 23°C


    Touch Dry [ISO] 6hrs 4hrs 2hrs
    Pot Life 24hrs 12hrs 8hrs



    Overcoating
    Substrate Temperature
    5°C 15°C 23°C
    Overcoated By Min Max Min Max Min Max Min Max


    VC 17 New Technology  24hrs  14days  10hrs  7days  8hrs  4days    
    VC 17m  24hrs  14days  10hrs  7days  8hrs  4days    
    VC 17m Biocide Free  24hrs  14days  10hrs  7days  8hrs  4days    
    VC 17m Eco  24hrs  14days  10hrs  7days  8hrs  4days    
    VC 17m Extra  24hrs  14days  10hrs  7days  8hrs  4days    
    VC Offshore with Teflon  12hrs  24hrs  6hrs  12hrs  3hrs  6hrs    
    VC Tar2  6hrs  10days  3hrs  6days  2hrs  3days    


    Note:Overcoating times have changed compared to VC Tar. If maximum overcoating times are exceeded, lightly sand the surface before overcoating.

    APPLICATION AND USE
    Preparation GRP: Use Super Cleaner to clean and fully degrease the surface then sand with 240 grade wet or dry paper. Rinse with fresh water and allow to dry.
    OSMOSIS PROTECTION: Apply 3-5 coats of VC Tar2. IMPORTANT: BEFORE APPLYING TO GRP, TEST HULL MOISTURE LEVELS; UNDER 5.0% (SOVEREIGN METER) WILL ACHIEVE BEST RESULTS.
    OSMOSIS TREATMENT: Remove existing paint from the gelcoat. Cut open and sand out all blisters and damaged areas. Leave the hull to dry out (normally 6-8 weeks in the autumn). If possible create a high temperature/low moisture condition for drying out. Once dry, fill in all craters with Watertite and sand smooth (substitute fillers, particularly polyester, are not suitable). Apply 7 coats of VC Tar2. Should you be in any doubt, consult a qualified marine surveyor.
    STEEL/IRON: Gritblast to Sa 2½. Use angle grinder on small areas. Apply 4 coats minimum of VC Tar2.
    ALUMINIUM/ALLOY: Clean and degrease with Super Cleaner. Mechanically abrade using aluminium compatible paper or low pressure grit blast using aluminium oxide. Pre-prime with a thin coat of Etch Primer. Apply 4 coats minimum of VC Tar2.
    LEAD: Clean and degrease with Super Cleaner. Rub down with an emery cloth or power wire brush. Rinse with fresh water and allow to dry. Apply 3 coats minimum of VC Tar2.


    Method Stir individual components well before use. Pour Curing Agent (in can under "hat") into Base and stir well. Wait a minimum of 15 mins for the air bubbles to disperse. VC General Thinner may be used (up to 5%) to aid application properties and to clean equipment. For optimum flow, apply paint 15 mins to 4 hours after mixing. Apply the following number of coats: GRP (Osmosis Protection) - 3-5; Previously painted (aged, 2-component only) - 3-4 (NB not to be used over old antifoulings); Steel/Aluminium/Alloy - 4 (min); Lead - 3 (min).


    Hints Mixing Stir contents of each part prior to mixing. Pour Curing Agent (in can under "hat") into Base and stir well. Wait a minimum of 15 mins for the air bubbles to disperse. Mix ratio is 7:1 by volume, as supplied.
    Thinner VC General Thinner.
    Thinning Up to 5% thinner may be used to ease application.
    Cleaner VC General Thinner.
    Airless Spray Pressure: 210 bar. Tip Size: 1580-2180.
    Conventional Spray Pressure: 2-3 bar. Tip Size: 1.5-2.0 mm. Thin 20-30% using VC General Thinner.
    Other VC Tar2 takes 5 days to cure fully and the surface may not be scratch resistant until then. Launch the boat according to the recommended launch time of the antifouling applied. Sanding may be required in a dusty environment.


    Some Important Points Do not use below 5°C. Do not apply when there is a chance of condensation forming on the substrate. Do not use above the waterline. Product temperature should be minimum 5°C/40°F and maximum 35°C/95°F. Ambient temperature should be minimum 5°C/40°F and maximum 35°C/95°F. Substrate temperature should be minimum 1°C above dew point and maximum 35°C.


    Compatibility/Substrates Suitable for use with GRP, Steel, Aluminium and Lead.


    Number of Coats 3-7. See application section


    Coverage (Theoretical) - 11.30 (m²/lt)


    Recommended DFT 50 microns dry
    Recommended WFT 80 microns wet


    Application Methods Brush, Roller, Conventional Spray, Airless Spray

    TRANSPORTATION,STORAGE AND SAFETY INFORMATION
    Storage GENERAL INFORMATION:
    Exposure to air and extremes of temperature should be avoided. For the full shelf life of VC Tar2 to be realised ensure that between use the container is firmly closed and the temperature is between 5°C/40°F and 35°C/95°F. Keep out of direct sunlight.
    TRANSPORTATION:
    VC Tar2 should be kept in securely closed containers during transport and storage.

    Safety GENERAL: Read the label safety section for Health and Safety Information, also available from our Technical Help Line.
    DISPOSAL: Do not discard tins or pour paint into water courses, use the facilities provided. It is best to allow paints to harden before disposal.
    Remainders of VC Tar2 cannot be disposed of through the municipal waste route or dumped without permit. Disposal of remainders must be arranged for in consultation with the authorities.

    IMPORTANT NOTES The information given in this sheet is not intended to be exhaustive. Any person using the product without first making further written enquiries as to the suitability of the product for the intended purpose does so at their own risk and we can accept no responsibility for the performance of the product or for any loss or damage (other than death or personal or injury resulting from negligence) arising out of such use. The information contained in this sheet is liable to modification from time to time in the light of experience and our policy of continuous product development.

    , International, the Akzo Nobel logo and other products mentioned in this publication are trademarks of, or licensed to Akzo Nobel. ©Akzo Nobel 2008. Teflon® is a registered trademark of E.I. du Pont de Nemours and Company used under license by International Paint LLC.

    Regional Addresses
    Head Office
    International Paint Ltd
    P O Box 20980
    Oriel House
    16 Connaught Place
    London W2 2ZB
    United Kingdom
    tel: +44 (0) 171 479 6000
    fax: +44 (0) 171 479 6500
    European Region
    International Paint Ltd
    Stoneygate Lane
    Felling, Gateshead
    Tyne & Wear NE10 0JY
    United Kingdom

    tel: +44 (0) 191 469 6111
    fax: +44 (0) 191 438 3977
    Asia Region
    International Paint Singapore (Pte) Ltd
    449 Tagore Industrial Avenue
    01-03 Hong Joo Industrial
    Building
    Singapore 787820

    tel: +65 6453 1981
    fax: +65 6453 1778
    Australasia Region
    International Paint
    115 Hyde Road
    Yeronga, Brisbane
    Queensland 4104
    Australia

    tel: +61 (0) 7 3892 8866
    fax: +61 (0) 7 3892 4287
    North America Region
    International Paint LLC
    2270 Morris Avenue
    Union
    New Jersey 07083
    USA

    tel: +1 (0) 908 686 1300
    fax: +1 (0) 908 686 8545
    South America Region
    International Paint
    Rod Rap tavares, KM 18.5
    Predio Administrativo 11
    Butanta CEP 05577-300
    Sao Paulo, Brazil

    tel: +55 (0) 11 3789 2000
    fax: +55 (0) 11 3789 2200


    Ref:
    Issue Date:
    Supersedes:
    05000103
    3-Jun-2008
    31-Mar-2008